Production Capacity: 3000000
Delivery Date: 7 days after recieve deposi...
Circuit resistance: 50
Elec feature: 250V/10A 125V/16A
temperature tolerance: ±5 ,±3,±2
Means of Transport: Ocean,Land,Air;EXPRESS ,DHL...
Packing: cartons
Open temp range: -10-250
Insulation resistance: 100
life cycle: 100000
Certificate: CQC VDE CE CB TUV

250V/10A 125V/16A
CQC VDE CE CB TUV
-10-250 'C action temperature
187series or 250series terminal

Detailed Auto Thermostat Engineering Description:
This KSD301 thermostat is used either as temperature control and safety limit for household electric appliances and widely applicable for coffee maker, water heater, immersion heaters, electric cookers, microwave ovens, automatic toasters, etc.
Technical parameters:
1.Electrical parameters:
a.CQC, VDE, UL, CUL? AC250V 50~60Hz 5A / 10A / 15A (Resistance load)
b.UL AC 125V 50Hz 15A (Resistance load)
2.Action temperature range: 0~240°C (Optional), temperature accuracy:±2 ±3 ±5 ±10°C
3.Recovery and action temperature difference: 8~100°C (Optional)
4.Connection method: Insert the terminal 250# (bending angle: 0~90° optional); Insert the terminal 187# (bending angle: 0~90° optional; thickness: 0.5, 0.8mm optional)
5.Lifespan: ≥ 100,000 times
6.Electrical strength: No spark or breakdown for 1min at AC 50Hz 1800V
7.Contact resistance: ≤50mΩ
8.Insulation resistance: ≤100MΩ
9.Junction method: Constant-closed: the contact point disconnects when temperature rises; and contact point connects when temperature falls;
Constant-opened: the contact point connects when temperature rises; and contact point disconnects when temperature falls.
10. Casing protective class: IP00
11. Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device.
12. Installation method: installed for KI031 series: general moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole.
  
Product technical drawings
name
instruction
name
Instruction
1
case
Ceramic
7
moving
moving contact(3.0)
2
static
static Contacts
8
static
stationery contact(3.0)
3
moving
moving the reed
9
oriented
ceramic oriented frame
4
terminal
6.3 horizon terminal
10
fixation
fixed fixation
5
L rivet
long rivets(8.2)
11
bimetal
P675R bimetal
6
S rivet
short rivets(4.2)
12
action
ceramic action rod
Auto reset thermostat Structure and application:
The temperature controllers take bimetallic strip as the temperature-sensing unit. In case of normal operation the electrical appliance, the bimetallic strip is in a free state; the contact point is in a state of close/open. When the temperature reaches the action temperature, the bimetallic strip performs quick action, When the electrical appliance is cooled down to the recovery temperature, the contact point can not automatically reset , the people should press down the reset handle with acting force if the contact need to be reset once again, in this way ,the thermostat control the disconnection and connection of circuit.
1.It is necessary that you should only press down the reset handle when the temperature drop down by 20°C after the contact action.
2. In order to make sure the normal operation of thermostat, the vertical space between reset handle and thermostat temperature sensing cover should be more than 20.4mm.

Characteristics:
Stable performance, high accuracy, small size, lightweight, high reliability, long lifespan, less interference to radio

Precautions:
1.When adopting contact temperature sensing installation, the surface of the metal cover is required to be securely contacted with the installing surface of the controlled device. For ensuring the temperature sensing effect, it is required to coat thermal conductive grease or other similar thermal conductive medium on the surface of temperature sensor.
2.For reliable performance, collapse, loose or distorted top part of the cover is prohibited during installation.
3.Liquid in leakage into the controller, crackle in the casing and unauthorized change of external terminal position are prohibited.
4.When the product is used in the circuit with maximum current of 5A, the cable with copper core at section 0. 5-1mm2 is required for connection; When the product is used in the circuit with maximum current of 10A, the cable with copper core at section 0.75-1.5 mm2 is required for connection;
5.The product should be kept in a clean, dry and corrosive gas-free warehouse with good ventilation and at relative humidity below 90%, environment temperature below 40°C.
bigPhoto
 Ms. Kiki Zhao

Tel: 86-769-23078588
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

Dong Guan Kain Electronic Sci & Thec.Co.Ltd [China (Mainland)]


Business Type:Manufacturer
Country/Region: China (Mainland)

You May Like: